VantisVANTIS
Vantis Infinity Capsule in a dark spa suite with a client reclined inside the illuminated red interior, gold Vantis mark on the shell
← All equipment

Vantis Infinity Capsule

Single-occupant dry heat and vibration capsule. The client lies face up with the head outside the shell and the lid enclosing the body from the shoulders down. Ten modalities run from one panel. No water, no steam, no plumbing and no drain.

AV-FLT-1REV. 2026.1
Price
$52,000
Modalities
11
Session
30–45 MIN
Cabin temp
104–140 °F
Vibration
10 LEVELS
Weight
550 LB
Electrical
120V / 20A DEDICATED
From$52,000

What it does

Plainly, what happens in a session.

  • Eleven modalities in one shell, each switched independently at the front panel: cell resonance, far-infrared emitters, graphene film heat, a terahertz-emitter back mat, ten-level whole-body vibration, a rotating gyromagnetic field, chromotherapy, photon light wave, a negative oxygen ion generator, ozone sanitation and Bluetooth audio.
  • Graphene film heating converts electrical energy to heat at up to 99.15% efficiency and delivers it as far-infrared, so the cabin comes up in eight minutes and holds an even temperature end to end.
  • Far-infrared output sits in the 6 to 14 micron band, with the jade and bian-stone mat inlay emitting at 7 to 20 micron under load.
  • The gyromagnetic module runs a rotating pulsed magnetic field across the body — thousands of field lines per minute — selectable independently of the heat.
  • Photon light wave panels line the lid and cover the body from shoulders to feet, alongside the chromotherapy color array.
  • Vibration runs ten selectable levels through the bed platform; levels four through six are the standard operator setting for a general session.
  • A negative oxygen ion generator conditions the cabin air through the session.
  • An on-board ozone cycle sanitizes the empty cabin between clients in 10 to 15 minutes. Nobody may be in the room during the cycle, and the space is vented for 30 minutes afterward.
  • The client's head stays outside the shell for the whole session, which makes the capsule usable by people who will not tolerate a fully enclosed sauna or a float tank.
  • Bluetooth pairs to the client's own phone for music or audiobooks through the cabin speakers.
  • One dedicated 120V, 20A circuit runs the entire unit. No plumbing, no drain, no fill, no ventilation duct.

Why this one

What the cheaper unit does not do.

No corrosion exposure

Salt solution destroys hardware, floors, and adjacent rooms over time. A dry unit does not.

Eleven modalities on one control panel

Cell resonance, heat, vibration, terahertz mat, gyromagnetic field, chromotherapy, photon light wave, negative oxygen ion and ozone are all selected from a single front panel. There is no second controller and no app dependency.

Head-out design

The lid encloses the body from the shoulders down while the head remains in open room air. That removes the claustrophobia objection that costs float tanks and full sauna cabins bookings.

Sanitation built into the machine

The ozone cycle runs unattended between clients on a disposable non-woven liner. There is no water to test, treat, filter or dump.

Standard household service

One 20A branch circuit. A 240V feed, a drain, a make-up water line and a corrosion-rated room are all things this unit does not need.

Full specifications

AV-FLT-1 specification

Overall length
7 ft 10 in (94 in)
Overall width
3 ft 8 in (44 in)
Height, lid closed
3 ft 6 in (42 in)
Height, lid fully open
6 ft 6 in (78 in)
Net weight
550 lb
Crated shipping weight
700 lb
Crate size
100 in × 50 in × 50 in
Occupancy
Single occupant, supine, head outside the shell
Maximum occupant weight
300 lb
Maximum occupant height
6 ft 4 in
Modalities
11, individually switched
Heating
Far-infrared emitters plus graphene film panels, up to 99.15% electrical-to-thermal conversion
Far-infrared band
6 to 14 micron, with jade and bian-stone mat inlay at 7 to 20 micron
Back mat
Terahertz emitter mat with jade and bian-stone inlay
Cell resonance
Operator-selectable, front panel
Vibration
Whole-body platform, 10 selectable levels (4 to 6 standard)
Gyromagnetic
Rotating pulsed magnetic field, operator-selectable
Light
Chromotherapy color array plus photon light wave panels in the lid
Air
Negative oxygen ion generator
Sanitation
On-board ozone generator, 10 to 15 min cycle, cabin empty, room cleared and vented 30 min after
Audio
Bluetooth, pairs to the client's phone, cabin speakers
Control
Front panel with individual modality selection and session timer, plus a rear main power switch
Preheat
8 min at maximum heat setting
Session length
30 to 35 min standard, up to 40 min in cold months, 45 min maximum cabin run time
Cabin temperature
140°F standard, adjustable down to approx. 104°F for a low-temperature session
Consumables
Disposable waterproof non-woven liner per client
Booking slot
60 min including preheat, changeover and ozone cycle
Plumbing
None

Operating protocol

How a session runs.

  1. 01Run the ozone cycle before the first client of the block — 10 to 15 minutes, cabin empty and nobody in the room, then vent for 30 minutes.
  2. 02Power the unit at the red main switch on the rear of the shell.
  3. 03Enable the modalities for the session: cell resonance, negative oxygen ion, vibration level, far-infrared heat, terahertz mat, graphene heat, chromotherapy and gyromagnetic.
  4. 04Set far-infrared, terahertz and graphene to the maximum setting and preheat for 8 minutes. The client changes and drinks a glass of lightly salted water during preheat.
  5. 05Lay a fresh disposable waterproof non-woven liner over the bed surface.
  6. 06Seat the client, close the lid to the shoulders, confirm the head is clear and the temperature is comfortable, then trim the cabin to about 140°F. Keep the upper-cabin graphene setting moderate to avoid contact burns.
  7. 07Set vibration between levels 4 and 6 — the standard comfortable range out of ten.
  8. 08Run 30 to 35 minutes, or up to 40 minutes in cold months. Stay within earshot; the client's head is outside the shell and the lid opens from inside at any point.
  9. 09End the session, remove and discard the liner, wipe the interior down.
  10. 10Run the ozone cycle again for 10 to 15 minutes with the cabin empty and the room cleared, then vent for 30 minutes before the next client.

Site requirements

Whether it fits in your building, today.

Minimum clear room
8 ft × 11 ft
Recommended room
10 ft × 12 ft
Minimum ceiling height
8 ft (lid opens to 6 ft 6 in)
Minimum door opening
36 in clear, for a 700 lb crate on a pallet
Clearance, head / control end
24 in
Clearance, entry side
36 in
Clearance, other side and foot end
14 in
Floor
Level, sealed, non-porous, rated 100 lb / sq ft
Electrical circuit
One dedicated 120V, 1-phase, 60 Hz, 20A branch circuit, GFCI, NEMA 5-20R
Connected load
1,800 W (approx. 15 A draw)
Data / network
None. Bluetooth audio pairs to the client's phone.
Ventilation
Room must be vacatable and ventilated for 30 min after each ozone cycle
Consumables
Disposable waterproof non-woven liners, one per client
Lead time
90–120 days to your door, made to order — varies by unit
Plumbing
None required
White glove install
$8,000, required — includes hands-on staff training

Use restrictions

Who the manufacturer excludes.

The manufacturer excludes the following groups from use. Screen every client before a session. This is not medical advice and Vantis makes no health claims.

  • Anyone under 18 or over 70
  • Pregnancy, nursing under three months, or menstruation
  • Implanted metal hardware — plates, pins, stents, cardiac or cerebral
  • Pacemakers or any implanted electronic device
  • Heart failure or known cardiac insufficiency
  • Uncontrolled high blood pressure (above 160/90 mmHg) or low blood pressure (below 60 mmHg diastolic)
  • Hyperthyroidism
  • Respiratory conditions including asthma, pneumonia or embolism
  • Kidney failure, dialysis, or malignancy
  • Epilepsy or a diagnosed mental-health condition affected by sensory stimulus
  • Open wounds, active skin disease or communicable infection
  • Diabetes with blood glucose below 5.0 mmol/L
  • Known sensitivity to magnetic or negative-potential fields
  • Anyone acutely unwell or within three days of surgery

Options and configurations

Configure the unit.

White label branding
Your logo and business name applied to the capsule, with custom colors and finishes — extra fee
Quoted
Custom shell finish
Matched panel color from the standard range
Quoted
Liner supply program
Standing shipment of disposable waterproof non-woven liners
Quoted
Spare emitter and mat kit
Backup far-infrared emitter set and terahertz back mat held on site
Quoted

What's included

In the price on the plate.

  • White glove install and hands-on staff training, $8,000 — required on every unit, not optional
  • All eleven modalities as standard — nothing on the panel is an upcharge
  • Terahertz back mat with jade and bian-stone inlay
  • Bluetooth cabin audio and on-board ozone sanitation
  • Freight to the loading dock and inside delivery to the installed room
  • Four hours of operator training for your staff
  • Full spec, site requirement, operating and client-screening documentation before purchase
  • Five-year cabinet warranty, three years on thermal and control systems

Run your numbers

Vantis Infinity Capsule, against your own figures.

Your inputs

Result of your inputs

Monthly revenue from this unit

Based on the numbers you entered. Not a projection, estimate, or representation of results.

Documentation

Download the full spec sheet.

Complete specification, site drawings and electrical requirements for the AV-FLT-1. From $52,000.

Request a quote

Pricing and site requirements in one package.